<LOGO>
FM Transmitter Measurement Report
Created: 2025-05-10 15-11-54
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 5/5, 58 dBuV SANDELS
Pilot RDS Phase Difference
4.7 kHz 5.7 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
10 kHz 14 kHz 16592 3,8030
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
1,9 dBr 3,94 dBr 5,9 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
94.7 MHz -
FM Scope Max at: 14 kHz MIN: 10 kHz % above 76 kHz: 3,8030 Acquired: 2025/05/10 15.10.50 Total samples: 16592 Equivalent time: 0:13:49 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600 800
FM Scope MAX: 5,9 dBr MIN: 1,9 dBr AVE: 3,94 dBr % above 12,2 dBr: 0,0 Last value: 3,6 dBr (2025/05/10 15.10.50) 14.56 14.58 15.00 15.02 15.04 15.06 15.08 15.10 0 2 4 6 Pm [dBr]